Heating and Cooling Solutions

DVM S Max Heat®

  • Available Capacities
  • 6 to 24 tons

Cold Remedy.

The ideal solution for the harshest of colds. Our DVM S Max Heat® provides 100% heating performance at -13°F (-25°C) to keep you comfortable.

6 and 8 ton single modules available in both Heat Pump and Heat Recovery. Connect up to 3 units for system capacities up to 24 tons.

  • AC Features

    • image description

      HIGH HEATING PERFORMANCE 

      With the ability to produce 100% heating capacity at -13°F (-25°C), our DVM S Max Heat® systems are a smart solution for commercial buildings in areas that experience low outdoor ambient temperature.

    • image description

      LOW AMBIENT COOLING 

      Compatible with both DVM S Max Heat® Heat Pump and Heat Recovery models, our Low Ambient Cooling Hood provides 100% cooling capacity down to -13°F (-25°C). Advanced integrated logic allows for louver positioning based on outdoor unit high pressure, outdoor ambient temperature, compressor compression ratio, and operating mode.

    • image description

      ULTIMATE ZONING SOLUTION 

      DVM S Max Heat® systems allow for precise temperature control in multiple zones, providing comfort to a wide range of occupants. Heat Recovery systems add the capability to heat and cool separate zones simultaneously making it a superior choice.

    • image description

      WIDE VARIETY OF INDOOR UNIT OPTIONS 

      Our indoor units offer superior performance, flexible installation, and ease of operation. These units employ innovative technologies, like our WindFree™* Cooling technology, to optimize comfort in any environment. With over 10 different types of indoor units, ranging from 5,000 to 96,000 Btu/h, there are solutions for almost any application.

    • image description

      EXTENDED PIPING LENGTH 

      DVM S Max Heat® systems offer installation flexibility with extended piping length up to 722 ft., vertical separation up to 361 ft. between the outdoor unit and furthest indoor unit, and 164 ft. between the highest and lowest indoor units.  

    • image description

      CONTROL INTEGRATION OPTIONS

      A number of control options are available to fit a variety of project needs, from simple local controllers to full central control options. This allows the capability to integrate into any Building Management System (BMS) through BACnet, LonWorks, or Modbus.

    • image description

      ADVANCED COMMISSIONING AND SERVICE

      DVM S Max Heat® systems are equipped with a removable EEPROM chip on the main circuit board to store startup information, system settings, serial number, and other field programmed data. This allows for ease of startup, commissioning, product registration, and future service work when using Samsung service software (S-Net Pro2).

  • Brochures & Literature

    • Pairs With




      360 Cassette

      WindFree™*
      4-Way Cassette
      WindFree™*
      Mini 4-Way Cassette






      WindFree™*
      1-Way Cassette
      Duct S

      Slim Duct







      High Static Pressure
      (HSP) Duct
      Outside Air Processing
      (OAP) Duct
      Multi-Position Air Handler (MPAH)






      WindFree™* 2.0
      MaxUnder Ceiling






      Big Ceiling

      Floor Standing
      (concealed type)
      Floor Standing
      (exposed type)








      Fresh Access™ Split-DOAS

    • Controls




      Wi-Fi Adapter

      DMS 2.5

      DMS 2.5
      + BACnet Gateway






      DMS 2.5
      + LonWorks Gateway
      Pulse Input Module
      (PIM)
      Touch Centralized
      Controller








      Modbus Adapter

    Additional Information

    Product Registration Required. 
    Conditions Apply.


    The AHRI Certified® mark indicates Samsung's participation in the AHRI Certification program. For verification of individual certified products, go to www.ahridirectory.org.


    Available for download on the Google™ Play store and App Store®. A network connection is required. Samsung application account is necessary.








    *The WindFree™ unit delivers an air current that is under 0.15 m/s while in WindFree™ mode.  Air velocity that is below 0.15 m/s is considered “still air” as defined by ASHRAE 55-2013 (American Society of Heating, Refrigerating, and Air-Conditioning Engineers).

    DVM-Pro design software is available for download at SamsungHVAC.com.

    Choose Your Language